Definition Type: Element
Name: TankType
Namespace: urn:cidx:names:specification:ces:schema:all:4:0
Type: nsA:TankTypeType
Containing Schema: CIDX_CeS_v4.0_CommonComponents.xsd
Abstract
Documentation:
Code used to provide additional information on tank equipment conforming to the ADR regulations L4AV HIN-UN SUPPLIER Source: ADR regulations chapters 4.3.3.1 (class 2) and 4.3.4.1 (class 3 to 9) Details of the code: 1st: Required type of tank 2nd: Calculation of pressure 3rd: Openings 4th: Safety valves / devices Example: L4AV L: Tank for substances in liquid state 4: Calculated minimum pressure of 4 bar A: Tank with bottom filling and discharge openings with 2 closures V: Tank with a venting system, but no flame trap
Collapse XSD Schema Diagram:
Drilldown into Domain in schema cidx_ces_v4_0_commoncomponents_xsd Drilldown into TankTypeType in schema cidx_ces_v4_0_commoncomponents_xsdXSD Diagram of TankType in schema cidx_ces_v4_0_commoncomponents_xsd (CIDX eChemical Standard)
Collapse XSD Schema Code:
<xsd:element name="TankType" type="TankTypeType">
    <xsd:annotation>
        <xsd:documentation>
            <Documentation>
                <Description>Code used to provide additional information on tank equipment conforming to the ADR regulations</Description>
                <SampleData>L4AV</SampleData>
                <CodeListName>HIN-UN
SUPPLIER</CodeListName>
                <Comments>Source: ADR regulations chapters 4.3.3.1 (class 2) and 4.3.4.1 (class 3 to 9)
Details of the code:
1st: Required type of tank
2nd: Calculation of pressure
3rd: Openings
4th: Safety valves / devices
Example: L4AV
L: Tank for substances in liquid state
4: Calculated minimum pressure of 4 bar
A: Tank with bottom filling and discharge openings with 2 closures
V: Tank with a venting system, but no flame trap</Comments>
            </Documentation>
        </xsd:documentation>
    </xsd:annotation>
</xsd:element>
Collapse Child Attributes:
Name Type Default Value Use
Domain nsA:Domain Required
Collapse Derivation Tree: